Nistune Type 1 Diagnostics Technical Notes V1.2 (JECS ECCS 1984-1989 Legacy Engine Control Units) Copyright 2004, 2005, 2006, 2014 Nistun
4. Advanced USB Diagnosis If Nistune does not connect with the above steps then try checking the connection directly to the ECU without Nistune soft
5. USB Communications works but drop out frequently or various error messages appear Things to check 1. Does your laptop have a part of its earth c
6. Nistune reports the error 'Cannot connect - Invalid CONSULT valid in address file' or ‘Consult checksum error’ or ‘Invalid USB ECU addres
7. When I try to make a change to the maps, tables or constants and then disconnects Type 1 Rev A/B boards only This means that Nistune has attemp
WARNING If your ECU pulses the fuel pump, injectors, fuel regulator, flashes LEDs randomly (or they just stay on when they shouldn’t) or your engine
Solving USB Communications Device Problems 1. PC / Nistune fails to see the Type 1 board When you connect to Nistune using a Type 1 board, your PC
The ‘Nistune USB Communications’ or ‘Nistune Type 1 board’ device should show up here as working. If not then reinstall Nistune and ensure the driv
If the device does not show up at all in Device Manager then obtain the program USBview.exe and check the Nistune USB Communications Device / Nistune
2. Connect to the USB device, it connects and then disconnects You may receive an error ‘USB Consult not connected’ or ‘No data received’ error mes
6. Special case for Type 1 boards sold in 2008 (Revision 1, 2 limited to release of 24 boards) Check your ECU Nistune patched software is running c
3. Checking CPU connector header (a) First check your cable connections are working. You need a multi meter and put it in to ‘continuity mode’ which
It might be necessary to clean up or push the probes through conformal coating which is a lacquer which protects the circuit boards from corrosion.