Nistune Z32 ECU Modifications for R33 RB25DET Skyline Installation
Revision 10 – 26 May 2013
Thanks to Eric at DTA Motorsports and Andrew H for their help with previous versions.
Many thanks and credits to Skyline Stu for the Rev 10 version of this document.
Overview
Fitting of the Z32 ECU is a functional and cost effective way to tune the R33 RB25DET
Skyline when fitted with a NIStune board. The main ECU pin-outs are the same, so the
Z32 ECU will actually plug into the R33 without modification.
There are some secondary signals which differ between the two ECU’s. So for best
integration into a standard R33 Skyline we’ve provided some basic instructions detailing
the changes.
As a minimum it’s recommended to do the resistor modification to correct the Fuel
Temperature input – this will avoid incorrect fuel temperature measurements affecting the
tune (see Section 5).
Instructions are for modifying the Z32 ECU for a direct R33 plug-in. This saves re-wiring
the R33 harness - which means the standard ECU can easily be re-fitted if required. The
same outcome may be realised by modifying the wiring harness if you’d rather not modify
the ECU.
NIStune has provided a base image which consists of the Z32 base with R33 maps/tables
merged. Files can be found in the NIStune ROM pack (from V3 onwards) under the Type
2/ECR33_RB25 folder (refer downloads section at www.nistune.com).
These files should provide a good starting point for tuning. Experience has shown that an
RB25DET running the standard 370cc injectors and standard AFM will run quite well
before any tuning even takes place.
Base images are configured for Series 1 R33 engines. Series 2 use a different airflow meter, so be
sure to change the airflow meter in NIStune (Operations, Change Mass Airflow Meter) when you
first connect to your ECU. Response curves for both airflow meters are very similar, so this should
have minimal affect on the rest of the tune (K constant, load scales etc.).
Seitenansicht 0
1 2 3 4 5 6 ... 12 13

Inhaltsverzeichnis

Seite 1

Nistune Z32 ECU Modifications for R33 RB25DET Skyline Installation Revision 10 – 26 May 2013 Thanks to Eric at DTA Motorsports and Andrew H for

Seite 2

6) Air Conditioner FICD – pin 36 * Series 2 only Series 2 FICD functionality requires routing a wire from the Z32 FICD output driver (pin 5 of IC6

Seite 3

Supporting Data (Series 1 RB25DET)

Seite 4

Z32 ECCS DIAGRAM

Seite 5 - Link pins 19 – 34

R33 (Series 1) ECCS DIAGRAM

Seite 6 - * Series 1 and Series 2

Notes 1) The Z32 uses a switch on the TPS (Throttle Position Sensor) to sense closed throttle. R33 RB25 S1 does not. The Z32 ECU will use default “li

Seite 7

Important Soldering Notes If you already have the equipment, you should know how to use it confidently. Tools Required Temperature Controlled Solder

Seite 8

1) Knock Sensor inputs – pin 23/24 The R33 RB25 engine uses twin knock sensors with Nissan part number 22060-56S10 (shared with R32 RB20DET). Z32 V

Seite 9 - Cut Exhaust Temp Lamp

2) O2 Sensor inputs – pin 29/55 RB25 uses a single O2 sensor. Z32 uses twin. Link the O2 sensor input for RB25 (pin 29) to pin 55 so both O2 sensor

Seite 10 - * Series 2 only

Remove R613 Surface mount component resistor 4) Fuel Temperature input – pin 36 * Series 1 and Series 2 Z32 ECU uses a fuel temperature sensor

Seite 11

Bottom side of ECU put 2.2K ohm resistor in parallel to R252 to put Z32 ECU Fuel Temp input to a valid reading. Add 2.2K resistor inline with ECU R

Seite 12 - Z32 ECCS DIAGRAM

5) Exhaust Over Temp Output – pin 33 * Series 1 and Series 2 Z32 ECU uses this line to drive the FICD (Fast Idle Control Device) – for idle up wh

Seite 13 - R33 (Series 1) ECCS DIAGRAM

Series 2 Series 2 has the FICD wire connected to pin 36. Cut the track to isolate pin 33 so the EGT lamp does come on when the FICD activated. Do t